Arranco el Invierno conocé nuestras increíbles ofertas y promociones en miles de libro  Ver más

menú

0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional
portada Echocardiographic Predictors of Response to Parenteral Solutions (en Inglés)
Formato
Libro Físico
Idioma
Inglés
N° páginas
52
Encuadernación
Tapa Blanda
Dimensiones
22.9 x 15.2 x 0.3 cm
Peso
0.09 kg.
ISBN13
9786207044634

Echocardiographic Predictors of Response to Parenteral Solutions (en Inglés)

Luis Arancibia (Autor) · Our Knowledge Publishing · Tapa Blanda

Echocardiographic Predictors of Response to Parenteral Solutions (en Inglés) - Arancibia, Luis

Libro Nuevo

$ 93.355

$ 116.693

Ahorras: $ 23.339

20% descuento
  • Estado: Nuevo
Origen: Estados Unidos (Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el Viernes 19 de Julio y el Martes 30 de Julio.
Lo recibirás en cualquier lugar de Argentina entre 1 y 3 días hábiles luego del envío.

Reseña del libro "Echocardiographic Predictors of Response to Parenteral Solutions (en Inglés)"

The response to parenteral solutions was investigated in critically ill patients, with the use of indicators of ventricular preload by echocardiography, in 36 patients admitted to the hospital as critically ill, comorbid history, hemodynamic parameters, blood test data and echocardiographic measurements were taken before volume expansion, patients who increased their systolic volume and cardiac output greater than 15% after expansion were considered as responding, 300 cc. Of lactated Ringer's lactate was used as an expander. 25% of the patients did not respond to volume, in them the history of diabetes was a conditioning factor, among the parameters tested that we analyzed; Right Ventricular Tele Diastolic Volume (VTDVD), Left Ventricular Tele Diastolic Area (ATDVI) were significantly lower in those who responded compared to those who did not, by ROC curve was obtained that, VTDVD has an area under the curve of 0.98 (P=0.01, 95% [CI] 0.95-1.00), ATDVI has an area under the curve of 0.96 (P=0.00, 95% [CI] 0.90-1.00) to predict non-response to volume expansion with parenteral solutions.

Opiniones del libro

Ver más opiniones de clientes
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes